F-Conn Commercial Series Data Specifications
| Cable Types |
Series 59, 59Q, 6, 6Q, 11 |
| Braid Coverage Range |
60% through quad shield 60% tri, quad shield |
| Jacket Types |
PVC, PE and Plenum |
| Mechanical Requirements |
Specifications |
Limits |
Test Results |
| Corrosion Resistant |
BLCR GR-1503 3.2.1 |
Conforming materials |
Exceeds |
| Cable Application |
BLCR GR-1503 3.2.2 |
<20 lbs max insertion |
Exceeds |
| Cable Interface |
BLCR GR-1503 3.2.3 |
>40 lbs pull force |
Exceeds |
| Equipment Interface |
BLCR GR-1503 3.2.4 |
>10 matings without damage |
Exceeds |
| Equipment Interface |
BLCR GR-1503 3.2.4 |
>60 in-lbs without damage |
Exceeds |
| Temperature Cycling with Humidity |
BLCR GR-1503 4.1 |
+70° F to +140° F to -40° F
must pass 3.2.3 after 3 days |
Exceeds |
| Loosening Torque |
BLCR GR-1503 4.2 |
>30 in-lbs after 3 days of 4.1 |
Exceeds |
| Moisture Migration |
SCTE IPS-TP-013 |
No dye penetration |
Exceeds |
| Salt Fog |
BLCR ASTM B 117 |
Return loss >30 dB @ 1 GHz |
Exceeds |
| Environmental Pollutants |
BLCR GR-1503 4.5 |
Return loss >30 dB @ 1 GHz |
Exceeds |
| Vibration |
BLCR GR-1503 4.6 |
Loosening torque >32 in-lbs |
Exceeds |
| Chemical Resistance Outdoor |
BLCR GR-1503 4.7 |
7 days exposure* |
Exceeds |
| UV Degradation |
BLCR GR-1503 4.8 |
7 days exposure* |
Exceeds |
| Ozone Degradation |
BLCR GR-1503 4.10 |
70 hours exposure* |
Exceeds |
| Electrical Requirements |
Specifications |
Limits |
Test Results |
| Insulation Resistance |
BLCR GR-1503 3.5.1 |
>5000 M @ 100 Vdc |
Exceeds |
| Dielectric Strength |
BLCR GR-1503 3.5.2 |
<1 KVac for 1 minute |
Exceeds |
| Insertion Loss |
BLCR GR-1503 3.5.3 |
<0.1 dB to 350 MHz
<0.2 dB to 700 MHz
<0.3 dB to 1 GHz |
Exceeds |
| Return Loss |
BLCR GR-1503 3.5.4 |
>30 dB to 1 GHz |
Exceeds |
| Shielding Effectiveness |
BLCR GR-1503 3.5.5 |
>95 dB to 300 MHz
>70 dB to 1 GHz |
Exceeds |
*Samples will not exhibit crackling, swelling or brittleness.
F-Conn Series connectors were tested to meet SCTE-IPS and Bellcore specifications.
Where both organizations have specifications for the same requirements,
F-Conn Series connectors were tested to the more rigorous specifications.
Specifications subject to change without notice.